The Emergency Fire Containment System is a fire & smoke containment and suppression system specifically designed to safely contain Consumer Portable Electronic Devices up to a 20” Laptop.

Your purchase of the EFCS system includes:

  • EFCS Bag Assembly
  • Attached Fire Suppression System serviced with suppression agent & Charged with compressed Nitrogen
  • 1- pair of Large Thermal-Guard Gloves
  • 1- Kydex Storage case with Installation FAA approved Fire Resistant Velcro
  • 1-Suppression system Depressurization & Servicing tool.
  • Owners Manual
 

The EFCS is categorized as carry on loose equipment by the FAA and therefore does not require Specific 8110-3 Burn Certifications. If you wish to Physically mount the EFCS storage container at a later time to your aircraft you may request specific Burn certifications at any time for additional fees.

 
  • Weight: Approximately 14.7 Lbs.
  • Weight with Storage Case: 19.5 Lbs.
  • Height: 20.5”
  • Width: 24"
  • Width of Storage Container: 25.5"
  • Maximum Depth at Suppression Cylinder: 4.5"
  • Maximum Depth of Storage Case at Suppression Cylinder: 5"
  • Max Temp Contained: 2600° F
  • Suppression Agent Cylinder Volume: 26 oz.
  • Suppression System Pressurized: 175 PSI Compressed Nitrogen
  • Suppression Agent –ColdFire As -40°F Certified A & B Wetting Agent, Recognized to Class C & D

 
 

24” Large Emergency Fire Containment System

Any Large Cabin Aircraft or Airliner or large Military aircraft to Include:

  • Boeing Jets
  • Airbus
  • Bombardier Global Series
  • Challenger ( 600 series)
  • Gulfstream (G-450 and Above)
  • Falcon (7x, 900, 2000)
  • Embraer –(Legacy 650)
  • Hawker 4000

Placement of EFCS

We recommend placement of EFCS between crew members and passengers so the EFCS can be accessed on the way to the incident. EFCS does not have to be stored in upright position.


Installation Procedures

The Emergency Fire Containment System (EFCS) may be mounted directly to a flat surface or the provided Storage Case may be Velcro mounted in any suitable safe location utilizing the provided 2” or 4” adhesive backed fire resistant Velcro. The EFCS may be mounted vertically or horizontally based on the needs of the individual installation. The EFCS storage case was designed to be hard mounted to the aircraft interior if desired. Hard mounting of the EFCS Storage Case requires a specific Supplemental Type Certificate (STC) Approval.

How To Use

When the first signs of a potential personal electronic device (ped) fire are detected, such as burning smell or visible smoke, move the EFCS to the incident, put on the thermal-gaurd gloves, lift open the upper flap and unzip. If possible, remove the battery and place inside the EFCS bag. If unable to safely remove the battery, place the entire device inside the EFCS bag. Zip the EFCS closed, fold down the upper flap and squeeze firmly to ensure a proper seal. Pull the arming pin to arm the suppression system and relocate the EFCS to a non-critical location in the aircraft. The suppression system will automatically deploy if the EFCS internal temperature reached or exceeds 220 degrees F, therefore cooling and extinguishing the fire. Should the temperature not reach 220 degrees F, the unharmed device may be removed upon arrival at your destination, and handed back to the owner.

EFCS Instruction Card

 

E.F.C.S. Instructions for Continued Airworthiness-

Initial Suggested Maintenance Items:

  • Update passenger briefing cards to indicate the designated location of Emergency Fire Containment System within your aircraft. Install a placard in visible location adjacent to the EFCS to clearly indicate its location.
  • Although the EFCS is categorized as Carry on Loose equipment it is optional to add the weight of the EFCS and storage container to the Weight and Balance Calculations for the aircraft.
  • The EFCS may be deferred and is not a part of the required equipment list at this time. It may be deferred if required for continued flight as part of Non-Essential Furnishing (NEF) items. Create a logbook entry in the aircraft logbook referencing the installation of the Emergency Fire Containment System. Retain the original EFCS certifications, 8110-3 Burn Certification for the E.F.C.S. and 8110-3 Burn Certification (if requested) for the provided storage container with the aircraft

Create & Comply with the following maintenance task cards for the E.F.C.S.

  • Monthly Interval Inspection Requirements – Task #: 25-60-00 EFCS-ICA Monthly
    Emergency Fire Containment System Monthly Inspection Due:
    Inspect the EFCS for the following items:

    • The Suppression System Pressure gauge on the EFCS is within the Green Arc (175 PSI)
    • The Arming Pin with lanyard is fully engaged and tamper proof seal is intact.
    • The User Instruction Card is free from Damage and attached to the EFCS.
    • The fire resistant gloves are in designated pocket and are free from damage.

  • Yearly Interval Inspection Requirements – Task#: 25-60-00 EFCS-ICA Annual

    Emergency Fire Containment System Monthly Inspection Due:
    Inspect the EFCS for the following items:
    • The Suppression System Pressure gauge on the EFCS is within the Green Arc (175 PSI)
    • The Arming Pin with lanyard is fully engaged and tamper proof seal is intact.
    • The User Instruction Card is free from Damage and attached to the EFCS.
    • The fire resistant gloves are in designated pocket and are free from damage.
    • There are no physical defects or wear noted to any part of the EFCS assembly.
    • The operating instructions are clearly visible.
    • The Storage Box is free from damage & defects
    • Weigh the EFCS assembly (the weight is calculated without the gloves and storage container) If the weight has increased or decreased substantially (1.5 Lb.) from the initial weight provided on the data plate contact Fire Containment Concepts.

  • 6 Year Interval Inspection Requirements- Task #: 25-60-00 EFCS-ICA 6 year
    Emergency Fire Containment System 6 year Recertification Due

    • Return to Fire Containment Concepts for Six Year Recertification-

  • 12 Year Interval Maintenance Requirement – Task #: 25-60-00 EFCS-ICA 12 year
    Emergency Fire Containment System 12 Year Inspection & Hydrostatic testing Due:

    • Return to Fire Containment Concepts for Hydrostatic Test & 12 Year Recertification-

*Please check our website at www.fcconcepts.com for the most current recommended maintenance procedures.

 

The Emergency Fire Containment System is covered by a 4 year Limited Warranty.

1) Limited 4 year Warranty:

Fire Containment Concepts (“Manufacturer”) provides to its customers a four (4) year Limited Warranty against defects in material or workmanship of the Emergency Fire Containment Systems (EFCS) Product (“Product”), subject to the terms and conditions described herein below. Manufacturer warrants that during the warranty period the product delivered to the original purchaser will be free from defects in material and workmanship so long as the product remains in the ownership of the original purchaser, Product has not been activated or deployed, Product has been properly stored in storage case, and Product has been properly inspected and maintained per Manufacturers Maintenance Procedures. The Manufacturer reserves the right to amend any or all of the maintenance requirements from time to time. The maintenance requirements in effect at any given time must be complied with in order to maintain warranty coverage. The warranties shall be valid from the date of shipment from the manufacturer to the purchaser.

2) Repairs Completed Under Warranty:

If a product complies in all respect with the warranty provisions set forth above, Manufacturer will make all adjustments, repairs, modifications, corrections, or replacements at Manufacturer’s expense; provided, however that Product has been properly inspected and otherwise treated in accordance with Manufacturer’s requirements, Operating Instructions, Maintenance Procedures, applicable service bulletins, and the provisions of this limited warranty, and provided that Product has not been activated or deployed. Manufacturer shall use its best efforts to make all adjustments, modifications, corrections, or replacements under this warranty within Thirty (30) Business days or less from receipt of a Product.

3) Repairs Not Covered by Warranty:

If Product fails to comply in any respect with the limited warranty set forth in Section 1, any and all repairs will be the sole responsibility of the original purchaser.

4) Return of Product under Limited Warranty Provisions:

Purchaser must complete the online Material Return Authorization (“MRA”) form located on the manufacturer’s website or contact the manufacturer to receive the MRA forms in another manner such as via mail, email, or fax. Manufacturer must receive written notice of failure of a Product to comply with this warranty within thirty (30) days of discovery of such failure. Purchaser shall return the defective Product to the Manufacturer or its Approved Representative. Purchaser shall pay all costs of shipping the defective part to and from Manufacturer or its Approved Representative. All items shipped to Manufacturer or its Approved Representative must be prepared for shipment in accordance with the requirements of the Maintenance procedures, must be adequately packed to prevent damage in transit, and, if desired, insured by Purchaser. All items returned for replacement shall be shipped prepaid to the Manufacturer’s current address provided on the MRA form. NOTE: IT IS THE SOLE RESPONSIBILITY OF THE PURCHASER OF THE PRODUCT TO SUBMIT AND CONFIRM RECEIPT OF THE MATERIAL RETURN AUTHORIZATION.

5) Service costs—Product Not Found Defective (No Fault Found):

In the event that Manufacture determines that any Product returned is not defective or not covered by this Limited Warranty, customer shall be responsible for service and handling charges 'No Fault Found' shall mean a returned EFCS that is damaged or fails to operate properly as a result of operator error, abuse, or misuse or other causes not covered by this limited warranty.

6) Failure to Maintain in Accordance with Manufacturer’s Maintenance Requirements:

Failure to service Product in exact and specific compliance with the Manufacturer’s prescribed Maintenance Requirements herein below or as amended from time to time shall immediately void this limited warranty.

7) Maintenance Requirements:

Purchaser shall, prior to, or simultaneously with shipment, send a separate written warranty claim to the Manufacturer or its Approved Representative, advising that an EFCS is to be shipped for Warranty claim purposes and shall include a description of the failure, and airway bill number. Purchaser is hereby authorized to use any Shipping Agent or as otherwise mutually agreed, for goods returned to the Manufacturer or its Approved Representative. Shipments are to be conspicuously marked with Purchaser's and Manufacturer’s name. Except when otherwise stated, all shipping and insurance shall be at the Purchaser's expense.

 

Current Maintenance Requirements

  • Monthly Inspection Requirement
  • Yearly Inspection Requirements
  • Product must be returned to Manufacturer every (6) six years from the Date of Manufacture for inspection, and recertification maintenance requirements
  • Product must be returned to Manufacturer every (12) twelve years from the Date of Manufacture for Hydrostatic testing, and 6 year recertification.

Note: Maintenance requirements do change. It is the EFCS owner’s responsibility to know and understand manufacturer’s maintenance requirements at all times. Failure to comply with those requirements, which may be different from those described above, WILL VOID WARRANTY COVERAGE.